DATAQ DI-158U DRIVER

The actual sample rate can then be read after you run Start method. Default value is The EventLevel property allows you to specify when you want the NewData event fired. To enable a digital channel, you need to use codes like this:. Failed to send key to DI

Uploader: Zura
Date Added: 11 January 2008
File Size: 29.97 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 99403
Price: Free* [*Free Regsitration Required]

Specify the Dataq serial data acquisition device model number you are going to use or find out which one you are currently using.

DI USB Data Acquisition Starter Kit

Fired when an error is detected by the control. There are multiple functions for this property Syntax: This method must be invoked after Start Applicable Devices: It serves as the entry point for the superkeys of site dafaq Example: NET programming interface, UltimaSerial ActiveX project is now in frozen state, meaning no more development to support newer Dataq USB device nor to improve its functionality for existing products.

For DI and DI, the rate channel has gain control. This function reports how many available new data points have filled the buffer since the last time data was retrieved using GetData. One frame is equivalent to one sample of each active channel. If do-158u enable more than one channel, you will have to sort out the data for each channel yourself.

There are multiple functions for this property. ddi-158u

To catch the Minimum reading of a specified channel in the duration of the test from the moment Start method is invoked to the moment of this method is invokedadd to the valid channel count mentioned above. DI is the default. xi-158u

Dataq Instruments Di-158u USB Data Acquisition Starter Kit

The default is 1 channel. Specify the COMM port serial port you datqa to use or find out which one you are currently using. The actual sample rate can then be read after you run Start method. GetDataEx returns waveform data to an integer array as binary data.

The specified integer must be between 0 and 32, PreTriggerLength should be zero PostTriggerLength should be zero if all data points above the level should be captured, or one if only the first one should be captured. Unsupported trigger channel Failed to send the unlock key to some older DATAQ devices or failed to send out the scanlist to new devices. Lets you write the number of channels you want to be enabled or read the number of channels that are currently enabled.

COM port is not available. Channel count is changed to 1 For most C programmers, a variant of integer array returned by GetData is not what they would like to handle.

The minimum throughput rate for other 1xx is: When you specify a sample rate, an attempt is made to report data at that sample rate. This returns the serial number of the device after you Start the device successfully.

This channel does not support alarm setting To access the data returned by GetData, you can take a look at the following example If you are using VB. Channel 8 is always digital input, Channel 9 is always Rate input, and Channel 10 is always a bit Counter input. If you need to enable channels with different combination, you can use UltimaSerial.

Count is an integer and defines the number of scans you are requesting.

The order of data points is: The EventLevel property allows you to specify when you want the NewData event fired.